EV Chargers ULCEENERGY STAR

Split-Type DC Fast Charging Cabinet

FEVD split-system DC fast charging platform: a 240-720kW power cabinet feeding up to ten charging terminals. Modular 30-40kW power modules, OCPP 1.6J, and NEVI-ready configuration for gas stations, fleet depots and highway corridors.

Split-Type DC Fast Charging Cabinet

Technical Specifications

Key Features

  • High efficiency ≥95%
  • Smart HMI with one-touch operation
  • Power cabinet + terminal split architecture
  • Input: AC 260-530 V, 45-65 Hz
  • Power factor ≥0.99 (≥50% load), THD <5%
  • Ethernet / 4G connectivity
  • IP55 protection, -25°C to +50°C operation

Specifications

  • 240-720 kW power cabinet ratings
  • Modular 30 kW / 40 kW power modules
  • Wide output voltage range: 200-1000 Vdc

Specification Table

Output

Cabinet ratings
240 / 360 / 480 / 640 / 720 kW
Output voltage
200-1000 Vdc
Max. current per connector
200 Adc
Outputs per cabinet
6 / 9 / 10 depending on rating
Power module
30 kW / 40 kW hot-swappable

Input

Input voltage
260-530 Vac
Input frequency
45-65 Hz

Performance

Efficiency
≥95% at 50-100% load
Power factor
≥0.99 at ≥50% load
THD
<5%
Metering accuracy
Class 1

Protection

Protection
Over-voltage, over-current, short-circuit, residual current, insulation monitoring

Mechanical

IP rating
IP55

Environment

Operating temperature
-25°C to +50°C

Communication

Protocol
OCPP 1.6J
Connectivity
Ethernet / 4G
  • Total output current for the 360 kW and 480 kW cabinets is being re-confirmed with our engineering team — request the datasheet for the exact figure before sizing cable runs.
  • The same FEVD platform also ships as an all-in-one cabinet from 30 kW to 160 kW; those models are listed separately in the table below.

Model Matrix

Every model number in this line, with rated power, outputs and electrical ratings. Request the datasheet for full parameter curves.

Split system

ModelRoleRated powerOutputsMax. currentOutput voltageInput voltageDimensions (W×D×H)ConnectivityQuote
FEVD21360*Power cabinet360 kW6200 Adc per connector200-1000 Vdc260-530 Vac1600 x 800 x 1950 mmEthernet / 4G / WiFi / Bluetooth Quote
FEVD21480*Power cabinet480 kW6200 Adc per connector200-1000 Vdc260-530 Vac1600 x 800 x 1950 mmEthernet / 4G / WiFi / Bluetooth Quote
FEVD21250*Charging terminal250 kW2200 Adc200-1000 VdcTBC1600 x 800 x 1950 mmEthernet / 4G / WiFi / Bluetooth Quote

All-in-one

ModelRoleRated powerOutputsMax. currentOutput voltageInput voltageDimensions (W×D×H)ConnectivityQuote
FEVD12030Floor-standing charger30 kW1100 Adc200-1000 Vdc260-530 Vac700 x 300 x 1700 mmEthernet / 4G / WiFi / Bluetooth Quote
FEVD21060Floor-standing charger60 kW2200 Adc200-1000 Vdc260-530 Vac700 x 501 x 1730 mmEthernet / 4G / WiFi / Bluetooth Quote
FEVD21080Floor-standing charger80 kW2200 Adc200-1000 Vdc260-530 Vac700 x 501 x 1730 mmEthernet / 4G / WiFi / Bluetooth Quote
FEVD21120Floor-standing charger120 kW2200 Adc200-1000 Vdc260-530 Vac700 x 501 x 1730 mmEthernet / 4G / WiFi / Bluetooth Quote
FEVD21160Floor-standing charger160 kW2200 Adc200-1000 Vdc260-530 Vac700 x 501 x 1730 mmEthernet / 4G / WiFi / Bluetooth Quote

8 models in this line · 3 awaiting final parameter confirmation · link any row with #model-<number>

Applications

Gas Stations
Commercial Fleets
Highway Corridors
Public Transport
Heavy-Duty Trucks
Custom / OEM Scenarios

可核验的认证资质

适用范围:UL 2202 第 3 版,直流快充设备。「仅两家」为公司声明;证书本身可在 UL Product iQ 独立查询核验。

常见问题

分体式直流充电系统和一体式充电桩有什么区别?

FEVD 分体系统把 240-720 kW 功率柜与充电终端分开布置:一台功率柜按规格可带 6、9 或 10 个充电终端,适合加油站、车队场站、高速走廊等多车同时充电的场景。同一 FEVD 平台也提供 30-160 kW 的一体式机型,适合紧凑场地。

有哪些型号?规格分别是多少?

功率柜覆盖 240 / 360 / 480 / 640 / 720 kW,由 30 kW 或 40 kW 热插拔功率模块组成,输出 200-1000 Vdc,单枪最大 200 Adc。型号、枪口数量与尺寸见上方型号矩阵,完整参数曲线请索取数据表。

该产品有美国市场所需的认证吗?

该系列具备 UL、CE、ENERGY STAR 认证。FBK POWER 是目前中国仅有的两家、直流大功率充电桩(480 kW 以上)已取得 UL 认证的企业之一,另一家为比亚迪。证书编号与 UL Product iQ 验证方式已在认证中心页公布。

支持美国 NEVI 补贴项目吗?

FEVD 分体平台提供 NEVI-ready 配置,适用于美国高速走廊及公共充电项目。询价时请说明项目所在州与资金渠道,我们据此配置系统。

后台协议与联网方式是什么?

OCPP 1.6J,支持以太网 / 4G 联网。计量精度 Class 1,50-100% 负载下效率 ≥95%,≥50% 负载时功率因数 ≥0.99,THD <5%。

可以定制(OEM/ODM)吗?

可以。支持品牌定制、固件定制与硬件修改,包括终端数量与充电终端布置方式。询价时请提供场地布局与目标功率。